ATI EGA Wonder Series 2, 3 & 4 Drivers

Install Instructions
SWITCH SETTINGS Power-Up Video Mode Monitor Type ATI Enhanced Features
Monitor Attached 1 2 3 4 5 6 7 8
MultiSync (see note) off on on off on off on Switch 8 enables the "enhanced"
features of the card. 
Turn this switch off if you
experience difficulties.
EGA off on on off on off off
RGB (& Composite) on on on off on on off
TTL mono off on on off off on off
25KHz (see note) off on on off off off on
Composite mono on on on off on on off
Compaq (see note) off on on off off off off
IBM Analog (see note) on on on off off on on

Notes:

  • OFF = OPEN, ON = CLOSED
  • Switches 5 and 6 on a PC or XT motherboard must be set to ON.
  • "MultiSync" monitors at this time tended to support 15-31.5kHz (NOT 31.5 and up), and used a 9-pin digital connector.
  • 25kHz monitor requires Jumper P8 set to connect pins 2 & 3 (not available on VIP).
  • Compaq Internal Monitor requires an "optional module" (no longer available).
  • IBM Analog monitor support is only available on the VIP

Default Jumper Settings:

EGAWONDER Series 1 EGAWONDER Series 2, 3 and 4 EGAWONDER 800 VIP
P3=2-3
P6=1-2
P7=1-2
P3=2-3
P4=2-3
P5=2-3
P7=1-2
P3 thru P6=2-3, P7=1-2
P8=1-2
P9=2-3
P11 thru P16=1-2
JP1=2-3
JP2=1-2
JP3=2-3
JP4=2-3
JP5 thru JP10=2-3
JP11=1-2

Download: